AM-4 Plumbing & Fire Fighting Designing & Drafting
Introduction & Basics
- Introduction, basics, units, conversions
- Scope & Future of MEP
- Applications of plumbing
- Standards in plumbing (IPC, UPC, NBC, ASPE, DEWA)
- Introduction to plumbing systems
- Type of plumbing systems
- Plumbing drawings
- Roles & responsibilities of plumbing engineers
Items in Drainage & Water Supply
- Plumbing items and fixtures
- Number of fixtures inside spaces as per IPC
- All fixtures in bathrooms and toilets
- All accessories in bathrooms and toilets
- All equipments in bathrooms and toilets
- All traps and wastes in plumbing systems
- Water closets, lavatories, urinals, bidet, shower tray
- Kitchen sink, service sink, janitor sink
- Bath tubs, jetted and air bath tubs
- Jetted and air bath tub accessories
- Bibcock, mixers, thermostatic mixing valves
- Floor traps, floor drains, floor cleanouts, roding eye, cleaning eye
- Parking drains, channel gratings, shower gratings, balcony drains
- P trap, U trap, Nanu trap, bottle trap, sediment bucket
- Click clack waste, popup waste
- Pipe hangers and supports
- Grease / oil interceptors
- Rainwater outlets and spouts
- Valves in plumbing systems
- Fittings and accessories in plumbing systems
Water Supply, Drainage Design
- Types of water closets flushing systems
- Plumbing equations, calculations and system design
- Pressure requirements in plumbing systems as per IPC
- Selection and location of pressure regulating valves (PRV)
- Water demand calculation, drainage flow calculations
- Water supply underground tank/reservoir sizing
- Water supply overhead tank/reservoir sizing
- Drainage underground tank/reservoir sizing
- Septic tank sizing
- Soak pit sizing
- Sump pit and Sump pump
- Sewage lifting tank sizing
- Hot water demand calculation
- Hot water system calculations
- Centralized hot water system design
- Water supply in buildings (gravity systems and boosted systems)
- Water supply and drainage fixture units for design
- Water supply pipe sizing as per flow rate (IPC)
- Water supply pipe sizing as per fixture units (IPC)
- Isometric layout making
- Gravity water supply system design and pipe sizing - manually and using software
- Booster water supply system design and pipe sizing - manually and using software
- Hot water supply system design and pipe sizing - manually and using software
- One pipe drainage systems
- One pipe partially ventilated drainage systems
- Two pipe drainage systems
- Single stack/double stack drainage systems
- Horizontal drain line sizing as per IPC
- Horizontal drain slope selection as per IPC
- Vertical drain stack sizing as per IPC
- Vent pipe sizing as per IPC
- Pressurized plumbing lines design
- Oil/Grease interceptor sizing
- Rain water Gutter & Pipe sizing
Pumps & Components Design and Selection
- Types of pumps in plumbing
- Water supply transfer pump design & selection
- Water supply booster pump design & selection
- Submersible pump design & selection
- Sewage pump design & selection
- Hot water recirculation pump design & selection
- Booster pump expansion vessel sizing
- Pump head calculation manually and using excel sheet
- Pump power calculations
- Net positive suction head (NPSHa, NPSHr)
- Selecting pumps using technical data sheets
External Plumbing System
- Manhole sizing and cover selection
- Manhole cover selection (light, medium, heavy duty)
- External drainage systems
- External water supply systems
- Manhole invert level, cover level, depth calculations
- Storm water drainage systems
- Roof drain design and selection
- Rain water Gutter & Pipe sizing
- Oil/Grease interceptor sizing
- Sewage treatment plant concept
Pipe Materials and Selection
- Water supply pipe materials and selection
- Drainage pipe materials and selection
Plumbing - Drafting
- Plumbing drawings preparation (tender, IFC, shop, as-built)
- Plumbing isometric drawings preparation
- Plumbing riser diagrams
- Plumbing project
Softwares & Tools
- IPC Data sheets
- MCQUAY PIPE SIZER - Cold/Hot water pipe sizing
- MS EXCEL - BOQ, QS, Cost Estimation, Pump selection
- AutoCAD - Drafting
Fire Fighting - Introduction and Basics
- Introduction to fire fighting systems
- Fire fighting standards (NFPA, NBC, UAE)
- Fire hazard classification
- Fire triangle concept
- Getting familiar with fire fighting drawings
Fire Extinguishers (NFPA 10, NFPA 2001)
- Fire class
- Fire extinguishers types
- Selection of fire extinguishers as per NFPA 10
- Mounting details and spacing of fire extinguishers
- FM200 system design and selection as per NFPA 21
- FM200 system cylinder volume calculation and selection
- Components of FM200 system
Sprinkler System Design (NFPA 13)
- Selecting type of sprinkler system for buildings
- Types of sprinklers (upright, pendent, sidewall)
- Sprinkler color codes, RTI
- Dry sprinkler system
- Wet sprinkler system
- Preaction sprinkler system
- Deluge sprinkler system
- Sprinkler system pipe circuits
- Valves and accessories for sprinkler system
- Sprinkler pressure requirements as per NFPA 13
- Sprinkler pipe routing
- Sprinkler pipe sizing (NFPA 13)
- Sprinkler K values
- Sprinkler water demand calculation
- Hazen Williams equation
- Manual hydraulic calculation
- Hydraulic calculation using Elite software
Standpipe and Fire Hose System Design (NFPA 14)
- Analyzing the building for standpipe system
- Dry riser system design & selection
- Wet riser system design & selection
- Fire hose reel cabinet set selection and location
- Landing valve selection and location
- Internal and external fire hydrants
- Fire brigade valve (breeching inlet)
- Valves and accessories for standpipe system
- Standpipe & fire hose system pipe routing
- Standpipe & fire hose system pipe sizing
- Standpipe system pressure requirements as per NFPA 14
- Hose stream water demand calculation
Fire Tank Design and Sizing
- Fire water demand calculation
- Fire water tank volume calculation and sizing
- Combined fire + domestic water tank sizing
- Underground and overhead tank sizing as per NFPA & NBC
- Types of fire tanks and materials
- Fire tank connections
Fire Pump Design (NFPA 20)
- Fire pump flowrate calculation
- Fire pump head calculation
- Fire pump set design & selection (electrical, diesel, jockey)
- Vortex inhibitors
- Fire pump & pump room components
- Valves and accessories for fire pump
Fire Alarm System (NFPA 72)
- Selection and placing of fire detectors
- Correcting detectors spacing as per NFPA 72
- Selection and location of manual call points
- Selection and location of sounders
- Control and monitoring modules
- Fire alarm control panel (FACP)
- Fire alarm circuit
- Wires and cables in fire alarm system
Foam System (NFPA 11, NFPA 16)
- Foam system working
- Foam system selection
- Design methods
- Design calculations
CO2 System (NFPA 12)
- Surface, deep-seated concept
- CO2 system working
- CO2 system selection
- CO2 design methods
- Design calculations using manual/software
Clean Agent System (NFPA 2001)
- Types of clean agents
- Inert gases and halocarbon agents
- System selection
- FM 200 system
- Flooding quantity
- Design calculations
Fire Fighting - Project
- Fire fighting drawings preparation
- Fire fighting isometric drawings preparation
Softwares & Tools
- NFPA/DEWA standards - Design calculations
- FM-200 Selector - Clean agent selection
- MS Excel - Design calculations
- Elite - Hydraulic calculation
- AutoCAD - Drafting